Product data
96
LINCS Configuration
707023-003
Gateway Circuit 004 (Channel to SDLC DAP)
Gateway Circuit 004 LINCS C8.2 Central Control
UPSTREAM CONNECTION
Line: CHP1
Link Profile: 01 (Channel/SNA)
PU Address: 11
DOWNSTREAM CONNECTION
Line: HSC1.1
Link Profile: 06 (SDLC/DAP)
PU Address: C2
Primary Group Addr: E0
PUID Override: _______
PF: 1-Menu 3-Def_Dflt 4-Add 5-Delete 7-Back 8-Forw 9-Default 10-Done
Gateway Circuit 005 (Channel to Ethernet - LLC)
Gateway Circuit 005 LINCS C8.2 Central Control
UPSTREAM CONNECTION
Line: CHP1
Link Profile: 01 (Channel/SNA)
PU Address: 12
DOWNSTREAM CONNECTION
Line: FET1
Link Profile: 08 (LLC)
Local SAP: 04
Remote LAN Address: 0200 2222 0000
Remote SAP:: 08
PF: 1-Menu 3-Def_Dflt 4-Add 5-Delete 7-Back 8-Forw 9-Default 10-Done
Gateway Circuit 006 (Channel to Ethernet - IP)
Gateway Circuit 006 LINCS C8.2 Central Control
UPSTREAM CONNECTION
Line: CHP1
Link Profile: 01 (Channel/SNA)
PU Address: 13
DOWNSTREAM CONNECTION
Line: FET1
Link Profile: 09 (TCP/IP)
Data Link ID: 4000 1174 0001 04
Remote IP Address: 192 000 222 201
Remote Data Link ID: 4000 2222 0002 08
PF: 1-Menu 3-Def_Dflt 4-Add 5-Delete 7-Back 8-Forw 9-Default 10-Done