Installation guide

8
SCON-3074 Configuration
707112-001
If the Configuration utility is entered for display purposes only (i.e., not entered for update),
then the supervisor password will not be displayed. If entered in update mode, then the password
will be displayed, and can be updated.
Machine Check Options
This field determines what LINCS will do if a machine check condition occurs. Options are:
Dump and No IML (default) - Dump data will be written to the disk, but LINCS will
not re-IML.
Dump and IML - Dump data will be written to the disk, and then LINCS will re-IML.
No Dump and No IML - LINCS takes no action.
No Dump and IML - LINCS simply re-IMLs.
It is recommended that you select the Dump and IML option in most cases.
The LINCS Operating System will dump to the hard drive C. Up to 8 dumps may reside on
the hard drive at on time, each in a separate dump directory. You can copy the dump files to
diskette(s) using the Copy Data Objects utility on the Media Management menu in Central
Control Mode, or FTP the dumps off through the network interface.
LCD Message When All Comm Links Okay
This message displays when the SCON-3074 is powered up and all configured communications
interfaces are communicating as they should. You may change this message to display some
other message. Up to 16 characters may be entered. Example: ‘SCON-3074 OK’
3270 LU Number Display
This field has the following toggle options:
Hex - This is the default option. If selected, 3270 LU numbers will be displayed in
hexadecimal format throughout all Central Control Utilities. This option is recommended
when configuring the SCON-3074 platform.
Decimal - 3270 LU numbers will be displayed in decimal format throughout all Central
Control Utilities.