Specifications

Table 32 lists power supply specifications for the PowerEdge R620.
Specification
1100W DC
1100W AC
750W AC
495W AC
Current consumption
32A (X2)
12A6.5A
10A5A
6.5A3A
Supply voltage
-48V to -60V de CC
100240VAC
1
100240VAC
1
100240VAC
1
Frequency
-48V to -60V de CC
50/60Hz
50/60Hz
50/60Hz
Heat dissipation
(BTU/hr max)
4416
4100
2891
1908
1
Auto-ranging
Table 33 details the environmental specifications for the R620. For the most up-to-date information,
see the
Dell PowerEdge R620 Systems Owner’s Manual
and the
Dell PowerEdge R620 Getting
Started Guide
on Support.Dell.com/Manuals. For additional information about environmental
measurements for specific system configurations, see www.dell.com/environmental_datasheets.
Temperature
Continuous
operation
10°C to 3C at 10% to 80% relative humidity (RH), with 2C max dew point. De-rate
maximum allowable dry bulb temperature at 1°C per 300m above 900m (1°F per 550 ft).
Expanded
operation
When operating in the expanded temperature range, system performance may be
impacted. When operating in the expanded temperature range, ambient temperature
warnings may be reported on the LCD and in the System Event Log.
10% of annual operating hours: C to 40°C at 5% to 85% RH with 26°C dew point.
Outside the standard operating temperature (10°C to 35°C), the system can operate down
to C or up to 40°C for a maximum of 10% of its annual operating hours. For
temperatures between 35°C and 40°C, de-rate maximum allowable dry bulb temperature
by 1°C per 175m above 950m (1°F per 319 ft).
1% of annual operating hours: C to 45°C at 5% to 90% RH with 26°C dew point.
Outside the standard operating temperature (10°C to 35°C), the system can operate down
to C or up to 45°C for a maximum of 1% of its annual operating hours. For
temperatures between 40°C and 45°C, de-rate maximum allowable dry bulb temperature
by 1°C per 125m above 950m (1 °F per 22 ft).
Expanded operation restrictions:
No cold startup below 5°C
Maximum altitude for the operating temperature must be 3050m (10,000 ft)
Express Flash PCIe SSD, GPU, and LRDIMM not supported
130W (4 core) and 135W processor not supported
Redundant power supplies required
Non Dell qualified peripheral cards and peripheral cards greater than 25W not
supported
Storage
40
o
C to 65
o
C (-40
o
F to 149
o
F) with a maximum temperature gradation of 20
o
C per hour