Spec Sheet
*CET is a trademark of CET Fire Pumps Mfg Ltd.
75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Telephone: 1-800-567-2719 Fax: 1-800-434-2613 www.fire-pump.com
SKID UNIT - READY PAC
ACCEPT ONLY THE BEST
A C E N T U R Y O F E N G I N E E R I N G F O R T H E B R A V E S T
The water tank shall be constructed of 1/2" thick polypropylene sheet stock with PolymarCo-PP™ resin. Water tank shall be welded
with Heavy Duty extruded joint. The material shall be of a certified, high quality, non-corrosive, stress relieved thermo plastic, black
in colour with a textured finish, and UV stabilized for maximum protection. The skid type water tank shall be of a standard
configuration and shall be so designed to have complete modular slide in capability. The unit shall incorporate transverse partitions
manufactured for 3/8" PT2E polypropylene which shall interlock with a series of longitudinal partitions constructed of 3/8" PT2E
polypropylene. All swash partitions shall be so designed to allow for maximum water and air flow between compartments and are
fully welded to each other as well as to the inside of the tank. The passenger side rear wall of the tank shall have a standard built
in sight gauge 3" in width, and 70% transparent.
WATER TANK
The tank shall be equipped with a combination vent/overflow and manual fill tower. The fill tower shall have a 8" x 8" x 8" square
hinged type cover. The tower shall be located in the right rear corner of the tank. There shall be a vent / overflow installed inside
and to the extreme rear of the tower approximately 2" down from the top. This vent / overflow shall be of a standard schedule 40
polypropylene pipe with minimum ID of 3". The vent / overflow shall be piped internally toward the front and exit out the front
tank wall with a 1/2" extension past the front tank wall. The tank cover shall be constructed of 1/2" thick PT2E polypropylene, black
in color, UV stabilized.
FILL TOWER & TANK COVER
The tank shall have a capacity of 200 U.S. gallons of water.
TANK CAPACITY
The floor of the tank shall be manufactured from 3/4" PT2E polypropylene. There shall be one (1) sump as standard per tank. The
sump shall be integral to the tank floor and be a minimum of 3/8" deep recessed into the floor. The sump shall not be visible from
or protrude through the bottom of the tank.
SUMP
There shall be two standard tank outlets located in the same vertical plane on the driver side rear wall of the tank. One (1) 2-1/2"
female NPT tank to pump suction fitting and one (1) 1-1/2" female NPT tank fill fitting with flow deflector.
TANK OUTLETS
There shall be a 1" tank drain to the rear side of the tank with a brass plug.
1" TANK DRAIN
The cover shall incorporate two (2) booster reel mounting blocks that shall accommodate two (2) each sliding nut fasteners. These
4" large mounting blocks shall be welded to the covers running from the rear edge of the tank forward to the front edge.
TANK MOUNTING BLOCKS