6.
Performance
The pump running under *normal conditions will give you these performances:
*
Normal conditions: geostatic height of 4’ 10” (1.5m), temperature de 59°F (15°C), water clear of sand and
debris, atmospheric pressure < 3280’ (1000m) from sea level
None conformance to the instructions given in this handbook can reduce the
performances given by the pump.
0
50
100
150
200
250
300
0 1 2 3 4 5 6 7 8 9 10 11 12
0
10
20
30
40
50
60
70
80
0 25 50 75 100 125 150 175
Flow (LPM)
Head (BAR)
Flow (GPM)
Head (PSI)
Flow (GPM / LPM) Pressure (PSI / Bar)
70 / 265 10 / 0.7
65 / 246 50 / 3.4
4
5 /
170
100 / 6.9
35 / 132 125 / 8.6