Item Brochure

WATER TANK
The water tank shall be constructed of 1/2” thick polypropylene sheet stock with PolymarCo-
PP™ resin. Water tank shall be welded with Heavy Duty extruded joint. The material shall be
of a certified, high quality, non-corrosive, stress relieved thermo plastic, black in color with a
textured finish, and UV stabilized for maximum protection. The skid type water tank shall be of
a standard configuration and shall be so designed to have complete modular slide in capabil-
ity. The unit shall incorporate transverse partitions manufactured for 3/8” PT2E polypropylene
which shall interlock with a series of longitudinal partitions constructed of 3/8” PT2E polypropyl-
ene. All swash partitions shall be so designed to allow for maximum water and air flow between
compartments and are fully welded to each other as well as to the inside of the tank. The pas-
senger side rear wall of the tank shall have a standard built in sight gauge 3” in width, and 70%
transparent.
FILL TOWER & TANK COVER
The tank shall be equipped with a combination vent/overflow and manual fill tower. The fill
tower shall have a 8” x 8” x 8” square hinged type cover. The tower shall be located in the right
rear corner of the tank. There shall be a vent / overflow installed inside and to the extreme rear
of the tower approximately 2” down from the top. This vent / overflow shall be of a standard
schedule 40 polypropylene pipe with minimum ID of 3”. The vent / overflow shall be piped
internally toward the front and exit out the front tank wall with a 1/2” extension past the front
tank wall. The tank cover shall be constructed of 1/2” thick PT2E polypropylene, black in color,
UV stabilized.
TANK CAPACITY
The tank shall have a capacity of 200 U.S. gallons of water.
SUMP
The floor of the tank shall be manufactured from 3/4” PT2E polypropylene. There shall be one
(1) sump as standard per tank. The sump shall be integral to the tank floor and be a minimum
of 3/8” deep recessed into the floor. The sump shall not be visible from or protrude through the
bottom of the tank.
TANK OUTLETS
There shall be two standard tank outlets located in the same vertical plane on the driver side
rear wall of the tank. One (1) 2-1/2” female NPT tank to pump suction fitting and one (1) 1-1/2”
female NPT tank fill fitting with flow deflector
1” TANK DRAIN
There shall be a 1” tank drain to the rear side of the tank with a brass plug.