User manual
Table Of Contents

Specifications - Digital Input
Parameter Min Typical Max Units
Low Level Input Voltage -0,3 0,8 volts
High Level Input Voltage 2 5,8 volts
Maximum Input Voltage
@Screw terminal(2)(3) -10 10 volts
@DB25 connector(2)(3) -6 6 volts
Specifications - Digital Output
Parameter Condition Min Typical Max Units
Output Low Voltage No Load volts
@Screw terminal(3) Sinking 1 mA 0,5 volts
@DB25 connector(3) Sinking 1 mA 0,19 volts
@DB25 connector(3) Sinking 5 mA 0,91 volts
Output High Voltage No Load 3,3 volts
@Screw terminal(3) Sourcing 1 mA 2,77 volts
@DB25 connector(3) Sourcing 1 mA 3,01 volts
@DB25 connector(3) Sourcing 5 mA 2,36 volts
Short Circut Current (1)
@Screw terminal(3) 6,5 mA
@DB25 connector(3) 18 mA
Total Current (1) 25 mA
Output Impedance
@Screw terminal(3) 507 ?
@DB25 connector(3) 183 ?
1. Short-circuit proof single I/O only. Total current should be limited to less than 25 mA.
2. Keep voltages on Digital I/O below Maximum Input Voltage to prevent CEBO-LC from damage. This is
also true, if CEBO-LC is unpowered.
3. Protective circuit of Digital I/O on the screw terminals differs from that on the Sub-D jack.
22/63