User manual

Power on behavior
When connecting CEBO-LC to a host system, a positive voltage might occur on analog outputs. Pulse length
typically is about 6ms, peak voltage is about 1,5V. Maximum short-circuit current during this period is about
20mA. Please make sure that connected equipment is not negatively affected by this.
The same behavior is true when updating CEBO-LC firmware. Please remove all connections prior to initating
firmware update process with CeboLab.
Specification - Analog Outputs
Parameter Condition Min Typical Max Units
Nominal Output Range No Load -10 10 volts
@±2,5mA -9,875 9,875 volts
Resolution 12 bits
Absolute Accuracy 5% to 95% FS ±0,1 % FS
Integral Linearity Error ±4 counts
Differential Linearity Error ±2 counts
Error Due To Loading @ 100 µA 0,16 %
@ 1 mA 0,6 %
Souce Impedance 50 ?
Short Circuit Current (1) Max to GND 45 mA
Time Constant t.b.d. µs
1. Continuous short circuit will not cause damage.
21/63