Specifications

CES SUPPORT 407-679-9440 Page 20 MAN78 © CES 1998
6.0 Programmable Values and Customer Record
Item Description Range Representation Default Cust.
* Enter Programming mode
00 Program, exit program mode
1 Alert, call, enable 0,1 0 = off, 1 = on 1
2 Alert, call, duration 0 - 255 beeps, 0 = continuous 0
3 Alert, call, relay action 0 - 2 0 = none, 1 = on with beeps,
2 = on till acknowledged
1
4 Alert, autocall, enable 0,1 0 = off, 1 = on 1
5 Alert, autocall, duration 0 - 255 beeps, 0 = continuous 0
6 Alert, autocall, relay action 0 - 2 0 = none, 1 = on with beeps,
2 = on till acknowledged
1
7 Alert, emergency, enable 0,1 0 = off, 1 = on 1
8 Alert, emergency, duration 0 - 255 beeps, 0 = continuous 0
9 Alert, emergency, relay action 0 - 2 0 = none, 1 = on with beeps,
2 = on till acknowledged
1
10 Autocall, status digit 1 0 - 16 16 = not applicable 16
11 Autocall, status digit 2 0 - 16 16 = not applicable 16
12 Clock, year 0 - 99
13 Clock, month 1 - 12
14 Clock, day 1 - 31
15 Clock, hours 0 - 23
16 Clock, minutes 0 - 59
17 Clock, seconds 0 - 59
18 Display, call queue size 1 - 20 Number of calls 20
19 Display, call queue type 0,1 0 = FIFO, 1 = LIFO 1
20 Display, suppress timer 0 - 15 min, 0 = off 0
21 Emergency, status digit 1 0 - 16 16 = not applicable 16
22 Emergency, status digit 2 0 - 16 16 = not applicable 16
23 Polarity, PTT input 0,1 0 = active lo, 1 = active hi 0
24 Polarity, speaker enable o/p 0,1 0 = active lo, 1 = active hi 0
25 RS232 port, baud rate 0 - 4 0 = 300, 1 = 1200, 2 = 2400,
3 = 4800, 4 = 9600
2
26 RS232 port, arbitration 0,1 0 = send immediately,
1 = wait for poll
0
27 RS232 port, send time, date 0,1 0 = no, 1 = yes 1
28 RS232 port, polling address 0 - 99 1