4.0 Installation
Installation and programming of this CES product must be completed by a qualified two-way radio technician or
engineer. CES is not responsible for any operational problems caused by system design, outside interference, or
improper installation. Observe normal static prevention practices.
4.1 Radio Application/Interface Notes
Application Notes for selected radio models may be obtained by contacting your CES sales representative. If not
available, CES, at a nominal charge will prepare an application note for you. Please contact CES at 407-679-9440 for
further information.
4.2 Before Installing
The ARi-195e may be interfaced to almost any mobile radio. The ARi-195e should be programmed prior to field
installation.
4.3 Required Equipment for Installation
Communications service monitor or deviation meter with oscilloscope
Temperature-controlled soldering iron (fine tip, if surface mount components are used in radio)
Oscilloscope
Volt-ohm-meter
Alignment tool
4.4 Wire Interface Overview
Please read through the following descriptions to decide on the level of functionality required before undertaking the
actual installation. If you need help please call CES at 407-679-9440.
4.5 Radio Interface and Serial Cable
Radio Interface / Serial Connector Cable (DB25 male)
Pin
Wire Color
Function Direction Signal
1 Red Power 8 to 35v operational, 1 amp fused,
reverse polarity protected
2 Black Ground
3 Blue Ground
4 Dark Brown PTT in Input Z = 100k, -35 to 35v
5 Dark Green Speaker enable Output Open collector, no pull up
6 LightGreen Alert tone Output Z = 67k, cap coupled
7 White/Green
8 White/Blue TXS Output RS232
9 Violet RXS Output RS232
10 Yellow
11 Orange Alert relay, common Output Relay contacts
12 Light Brown Speaker mute, normally open Output Relay contacts
13 White Speaker mute, normally
closed
Output Relay contacts
14 Gray Power Output 8 to 35v
15 White/Red Receive audio unbalanced Input Z = 67k or 20k, cap coupled
16 Received audio balanced Input Z = 600 ohm, transformer coupled
17 Received audio balanced Input Z = 600 ohm, transformer coupled