Instruction manual
Connect Systems Inc. -Model TP-154 Page 13
CW ID characters and corresponding mm values may be obtained
from Table 1. The entry immediately following your message
must be 38 which means "end of message".
Example: To program KYZ 2584 the following mm sequence is
required in character positions 1-8: 10 24 25 27 30 33 29 38
-----------------------------------------------------------------
GANG PROGRAMMING TO PROGRAM
---------------- |
(Programs all 154 V
user slots at once)
COURTESY TONE *999#01#J#
CTCSS DURING HANG TIME *999#02#J#
BARGE IN CONTROL *999#03#J#
USER ENABLE/DISABLE *999#04#J#
RESERVE TONE *999#05#J#
HOG PENALTY ENABLE *999#06#J#
--------------------------------------
| In position J for all of the above |
| enter 1 for enable, 0 for disable. |
--------------------------------------
SUBSCRIBERS HANG TIME *999#07#mm#
mm 5-99 (.5-9.9 Seconds - .1 sec/step) [mm = 30 = 3 Sec's]
Note: There are no display codes for Global programming because
the programming affects 154 locations. You must view
subscriber programming on an individual basis.
-----------------------------------------------------------------
GLOBAL PROGRAMMING COMMANDS TO PROGRAM TO DISPLAY
--------------------------- | |
(These parameters affect all users) V V
LIST ALL GLOBALS ON DISPLAY OR CD-2 *000#00*
Downloads all global parameters to CD-2 or front panel display.
ANTI-KERCHUNKING TIME *000#19#mm# *000#19*
mm = 01-99, 0 to disable (.1 sec/step) [mm = 0 = Disable]
If enabled, repeater will not hang unless user keys down at
least as long as the time set. Does not affect pick up speed.