Instruction manual
Connect Systems Inc. - Model 9800 Page 14
1.2. Repeater Hang Time
Select 0-99 (0-9.9 seconds)
.1 sec increments per step
DEFAULT: 30 = 3.0 seconds
Selects the time in seconds that the repeater remains on the
air after the input signal drops. The time is equal to .1 second
times the number entered.
1.3. Repeater Activity Timer
0 = Disable
Select 10-99 (10-99 seconds)
1 sec increments per step
DEFAULT: 30 = 30 secs
Any single continuous mobile transmission exceeding the repeater
activity timer limit puts the repeater off the air. The activity
time in seconds is equal to the number entered. Entering 0
disables the activity timer.
GENERAL PHONE PATCH OPERATING PARAMETERS
1.4. Connect Code
0 = * Up
x - xxxx = Multi Digit Access
Protocol: *xxxx
DEFAULT: 0 = * up
Selects the phone patch access code. Enter 0 for * up operation.
Otherwise enter a one to four digit code. To access the patch
press * plus the selected code. (e.g. You want the access code to
be *387. Simply enter 387 P on the keyboard).
1.5. Secret Toll Override Code
x - xxxx = Multi Digit Override
Protocol: *xxxx
DEFAULT: 1234
This is a separate secret code that overrides the programmed toll
protection selected on lines 2.0. through 2.5. The access code
(1.4.), and the secret toll override code cannot start with the
same sequence. e.g. An access code of *2 would not be compatible
with a secret code of *2567. Select codes that are distinctly
different, such as Access Code = *56 and Secret Code = *3927.
Note: The secret Toll Override Code is inoperable if * up is
selected on 1.4. At least one additional digit must be
programmed, such as *7, *1 etc.