User's Manual

Module SRF310
U098.0.00-SRF310 User Manual
4
RF_PAEN Enable external PA Active High from SPI master
RF_HGM/BPA
Enable external LNA or
Read BPA jumper
Function not used in SRF310
Input to SPI master
RF Port Antenna connection 50 Ohm RF In/Out port
GND ground Low impedance ground
The 15010300 PCB assembly includes all circuits and features required for properly
implementing the SRF310 Type 4
Figure 3. 15010300, component side with shield and label.
Type 4 Module Application Engineering:
The Type 4 module requires that the host application provide suitable mechanical and
electrical mounting, control and power signals, an approved antenna that is properly mounted
and a proper RF transmission line to connect the RF port on the module to the antenna feed
port.
Mounting: This module must be mounted over a ground plane that extends at least 8mm from
the RF shield edges. All connections between the host application and the module are to be
soldered.
Power and Control Signals: All power, ground and control signal connections listed in Table 1
must be made, except RF_HGM/BPA.
RF Transmission Line: The RF connection between the module RF port and the antenna
feed port must have a nominal 50 Ohm impedance, have low insertion loss and be as short as
practical. Microstrip transmission line may be implemented as part of the host PCB. Coaxial
cable may be used to connect to an external antenna. Coaxial cable can be attached either with
a suitable connector or may be directly soldered to where the host PCB attaches to the RF port
of the module. If a replaceable external antenna is used the user-accessible external connection
must be a unique type such as RP-TNC, RP-SMA, etc.
Grounding: The SRF310 module must be connected to a good RF ground plane that is
part of the host circuit board.