Service manual
Web to PC Procedure
3-2 Revision L 96022
StorageTek Protected
■ Web to PC Procedure
To download the fir mware:
1. Create a folder or directory on the C drive where you will place the firmware.
2. Use your Web browser to access http://mpss.stortek.com
3. Click on Microcode under Tape.
4. Click on the desired product.
5. Click on the icon under the Download File column.
6. Save the file to the location you created in step 1.
Note: The file is a zipped file consisting of multiple files, including: release.prm,
flash97.exe, and the FSC dictionary.
7. Unzip the file, leaving the unzipped files in this folder.
Note: Use a Zip program, such as WinZip, to unzip the file.
■ PC to LLC Card Procedure
1. Attach your PC to the CSE port on the electronics module. This port connects to the
LLC card.
2. From your PC:
• For older PCs, click on Start>Programs>Accessories>Hyperterminal and open
a Hyperterminal session.
• For WIN2000 PCs, click on Start>Programs>Accessories>Communications
>Hyperterminal and open a Hyperterminal session.
3. Configure the connection within the file properties:
4. Click on
OK.
5. In the Hyperterminal window, click on
ENTER.
Table 3-1. Hyperterminal Connection
Older PCs WIN2000 PCs
Baud rate = 38,400 Baud rate = 38,400
Data bits = 8 Data bits = 8
Parity bit = None Parity bit = None
Stop bit = 1 Stop bit = 1
Direct to comm flow = none Hardware flow control = on