Service manual
96022 Revision L 2-27
StorageTek Protected
Reconfiguring the Library
■ Reconfiguring the Library
For some situations, you might need to change the configuration of the library. These
situations are described in the following paragraphs.
Note: If you change configuration settings in the library, make sure you also review the
configuration of your client server software to make sure the settings match.
Auto Clean
If you decide to enable the Auto Clean feature, you must set the Auto Clean field in the
Lib Info/Cfg Menu to On (see Table 2-1 on page 2-5), and insert cleaning
cartridges into the cells directly above the CAP. For more information about configuring
the library for Auto Clean, see:
• “Auto Clean Feature” on page 2-4
• “Configuring the Library” on page 2-4
• Figure 1-9 on page 1-13
Adding a Drive
If you added a drive to your library, you must access the Drive Info/Cfg Menu
and complete the required fields and reset the library.
See “Configuring the Drives” on page 2-6.
Adding Cell and Drive Capacity
Use the following table to order conversion bills for upgrading the cell capacity of your
library. The conversion bills include a personality module and set of instructions. You
must follow the instructions to have a successful upgrade.
Table 2-14. Conversion Bills for Upgrading Cell Capacity
Model Number Conversion
Bill
Description
L080-040 to L080-060
L080-060 to L080-080
101384 L80 20-cell capacity upgrade
L080-040 to L080-080 101388 L80 40-cell capacity upgrade