Service manual

96022 Revision L A-1
StorageTek Protected
A
Principles of Operation
This appendix provides information about the components and operation of the library.
Initialization Sequence
Initialization, also called an initial program load (IPL), occurs when you power-on the
library, or when you press the
RESET button.
The LLC card directs the initialization process, which consists of:
Robotic mechanism initialization and calibration
Camera calibration
Proximity sensor calibration
•Cell audit
Drive initialization
CAP audit
Cleaning cartridge cell audit
Hand initialization
Robot Initialization and Calibration
The robot moves to the different end stops:
1. Z motor calibration: The Z drive assembly moves from end stop to end stop. The
distance for this motion is compared against the Z drive parameters within the
firmware.
2. Theta motor calibration: The theta assembly moves from theta stop to theta stop.
The distance for this motion is compared against the theta parameters within the
firmware.
Camera Calibration
The robot moves to the vision calibration label above the CAP. The camera checks the
readability and accuracy of bar code information.
Proximity Sensor Calibration
The proximity sensor is aimed at the calibration label above the CAP to see if the sensor
indicator turns on. The hand assembly moves away from the label to test that the
indicator turns off. The sensor detects whether a cartridge is in a cell.