COPYRIGHT 2016 CERNO LLC.
General Product information
This product is suitable for indoor dry locations only.
This product can be dimmed with most standard dimmers.
Please see “Dimmer Compatibility” section of these
instructions for more information.
This product can mount to either a 4” square junction box
with a 3” round plaster ring or an octagon junction box.
CAUTION - RISK OF FIRE
This product requires installation by a qualied
electrician. Before installing be sure to read
all instructions and TURN POWER OFF TO THE
JUNCTION BOX
Attach the mounting plate
to the junction box using the
supplied #8-32 screws. Orient
and level the plate as shown in
the gure.
Attach a suitable ground wire
to the green screw in the
mounting plate
Installing the
Mounting Plate
2
Typical 3” Plaster Ring
Black (HOT)
White (NEUTRAL)
Ground
Mounting Plate
8-32 Screw
6
6
Attaching the Back
Connect the white xture wire to the neutral
power line with a wire nut.
Connect the black xture wire to the hot
power line with a wire nut.
Place all wires in the junction box.
Mount the back plate to the mounting plate
using the supplied #8-32 screws.
3
4
5
3
4
5
Junction Box
Back Plate
8-32 Screw
1
2
Wall
RED+
- BLACK