Engineer and Architect Specifications
ASC-1
Supervision of primary and backup amplifiers shall be
provided by a configurable plug-in module, model ASC-
1. The card shall plug into one slot in on the OMM-1
MXLV cardcage. Multiple ASC-1s may be used to
supervise additional amplifiers, both primary and
backup, as necessary. Through the use of the ASC-1,
backup amplification shall be provided on either a one
for one or one for multiple basis. Backup amplifiers shall
be capable of supporting primary amplifiers in any of 3
channels.
The amplifier supervisory card shall monitor the input
and output of each amplifier and check for proper audio
level. If a primary amplifier output is found to be defec-
tive, the supervisory card shall annunciate a system
fault condition and transfer operation to the backup
amplifier if supplied. The backup amplifier shall replace
the first failed primary amplifier.
The ASC-1 card edge fingers shall be gold plated for
highest reliability. The module shall be provided with a
key which when inserted into the OMM-1 card slot will
prevent any other type of module from being inadvert-
ently plugged into that slot.
The ASC-1 shall occupy one of the OCC-1 module sub-
addresses. This address shall be set using an on-board
DIP switch. A second dip switch shall be provided to
configure the ASC-1 operation.
ASC-2
Supervision of primary and backup amplifiers shall be
provided by a configurable plug-in module, model ASC-
2. The card shall plug into one slot in on the OMM-1
MXLV cardcage. It shall be capable of supervising one
primary and optionally, one backup amplifier. The ASC-
2 shall be used to supervise high power audio risers
when ICP remote control modules are controlling audio
zones. Multiple ASC-2's may be used to supervise
additional amplifiers, both primary and backup, as
necessary. Through the use of the ASC-2, backup
amplification shall be provided on either a one for one
or one for multiple basis.
The amplifier supervisory card shall monitor the input
and output of each amplifier and check for proper audio
level. If a primary amplifier output is found to be defec-
tive, the supervisory card shall annunciate a system
fault condition and transfer operation to the backup
amplifier if supplied. It shall also initiate a system
trouble condition regardless of whether or not a backup
amplifier is supplied.
The ASC-2 card edge fingers shall be gold plated for
highest reliability. The module shall be provided with a
key which when inserted into the OMM-1 card slot will
prevent any other type of module from being inadvert-
ently plugged into that slot.
The ASC-2 shall occupy one of the OCC-1 module sub-
addresses. This address shall be set using an on-board
DIP switch. A second dip switch shall be provided to
configure the ASC-2 operation.
Electrical Ratings
ASC-1
High Level Outputs:: 25V RMS, 7.2A,
70.7V RMS 2.4A
Backup Amp Input: 1V RMS
ASC-2
High Level Outputs: 25V RMS, 7.2A,
70.7V RMS 2.4A
Backup Amp Input: 1V RMS
NOTICE: The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics equipment will be considered a misapplication of Cerberus Pyrotronics equipment and as
such voids all warranties either expressed or implied in regard to loss, damage, liabilities and/or service problems.
Ordering Information
TABLE 1 - SPEAKER ZONE DECIBEL LOSS (25VRMS)
TABLE 2 - SPEAKER ZONE DECIBEL LOSS (70VRMS)
Model Description Part No.
ASC-1 Amp Supervisory Card 500-891187
Installation Instructions 315-091263
ASC-2 Amp Supervisory Card 500-892084
Installation Instructions 315-092085
Gauge
Length 14 AWG 16 AWG 18 AWG
(feet) (Loss in decibels)
200 0.2 0.3 0.6
400 0.5 0.7 1.1
600 0.7 1.1 1.6
800 0.9 1.5 2.2
1000 1.2 1.8 2.7
Gauge
Length 16 AWG 18 AWG
(feet) (loss in decibels)
200 0.04 0.06
400 0.07 0.11
600 0.11 0.17
800 0.14 0.22
firealarmresources.com