User manual
Page 91
4.12 CLI Error Messages
FibeAir 70 CLI issues three types of error messages:
• %Ambiguous command. This error occurs when the command entered can only
be partially interpreted. If possible, following the error message, a help syntax
line is returned to assist the User in correcting the command, as described in
Section 4.10.
For example:
FA-70> sh i
%Ambiguous command: sh i
show system, show bridge, show bridge-port, show eth,
show vlan-common, show vlan, show fdb, show fdb-table,
show ip, show rf, show arp, show cvlan-reg, show pep-vp,
show svid-xlat, show cfm-md, show crm-ma, show cfm-mep,
show cfm-ccm, show cfm-peer-mep-db
FA-70> sh i
• %Invalid input. This error occurs when the command entered includes an
attribute value that is outside of the range allowed. To assist the User, the CLI
will return the entered command with a question mark (?) added, immediately
following the erroneous parameter, as well as the entire command syntax.
For example:
FA-70> set vlan c1 5000 egress 1, 3
%Invalid input: set vlan c1 5000 (?) egress 1, 3
set vlan <comp-id-list> <vid-list> [fdb-id <fdbid>]
[egress <bridge-ports>] [untagged <bridge-ports>] where
<bridge-ports> are port names or none fdbid in range
1..64 and relevant for s-vlans only
• General Execution Errors. This error occurs when the command entered has
correct syntax but cannot be executed for some reason. Such error messages are
often application or object dependant. For more information, see the explanation
that accompanies the object that is specified on the command line, in Chapter 5.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299