User manual

Page 27
Figure 2-5 Installed FibeAir 70 Unit
2.3.7 Initial System Setup
Disconnect the DVM from the FibeAir 70 ODU by removin
g the probes from the
AUX port.
Carefully reinsert and tighten replace the AUX port protective seal.
Using the web-EMS or CLI configure the ODU to Adaptive Mode (See Section
5.14.1.1) on both local and remote units. Configure one unit to Role=Master and
the second to Role=Slave.
Save configuration and reset the ODU.
Following this action, and after ODU completed its reboot, the RF LED color
indicator on will change its color to green, indicating that the radio link is Up
(operative).
Each FibeAir 70 ODU will now perform automatic pairing.
The FibeAir 70 pair is now ready to be configured on the network.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299