Connect the opposite end of the Grounding Cable to the earth connection, typically
located on the mounting pole. In case earth connection is out of reach of the
Grounding cable, install alternative cable.
2.3.5 Cabling Connections
Cable connection panel details are shown in Figure 2-2.
Network connections are made according to port availability on the ODU. Before mapping
ODU connections, consider the following cabling restrictions:
• A power over Ethernet (PoE) connection can only be made via ODU port ETH1.
• Note that for each Ethernet port (ETH1 and ETH2) only one connection type can
be made on the ODU, either Ethernet (RJ45) or fiber optic (SFP).
1. Electrical Ground Outlet 5. Fiber Cable SFP Interface (SFP1)
2. Power Connector Interface (PWR) 6. Ethernet Cable RJ45 Interface (RJ2)
3. DVM Probe Interface (AUX) 7. Fiber Cable SFP Interface (SFP2)
4. Ethernet Cable RJ45 Interface (RJ1) 8. Reset Button (press for 5 seconds for restoring
factory defaults)
Figure 2-2 FibeAir 70 Connection Panel Details
Figure 2-3 FibeAir 70 DC Power Connector Pin-Out Diagram