User manual
Page 20
2.3.3 Mounting the FibeAir 70
Figure 2-1 shows details of the FibeAir 70 Mounting Assembly.
1. Unit Mounting Bolts 6. Azimuth Adjustment Lock Bolts
2. Back Mounting Bracket 7. Elevation Adjustment Lock Bolts
3. Front Mounting Bracket
8. Azimuth Fine Adjustment Screw (± 8°)
4. Quick Release Plate (Attached to ODU)
9. Elevation Fine Adjustment Screw (± 16°)
5. Quick Release Hook 10. Elevation Screw Tension Band and Pin
Figure 2-1 FibeAir 70 Mounting Assembly Details
Prior to mounting, loosen the Unit Mounting Bolts (), and remove one of the Bolts.
Separate and rotate the Front () and Back () Mounting Brackets by about 120
degrees so that the Assembly can to be attached to the mounting pole.
Place the Assembly on the mounting pole and rotate the Front and Back Mounting
Brackets to close the Assembly on the pole. Replace the Unit Mounting Bolt that
was removed.
Ensure that both Front and Back Mounting Brackets are attached
evenly to the pole, and are completely level.
Use the 1/2-inch open wrench to tighten the nuts on both Unit
Mounting Bolts. Temporarily tighten the Unit Mounting Bolts at this
stage to keep the Unit from moving freely.
The ODU is delivered with the Quick Release Plate () securely attached in a
vertical polarity position, by default.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299