User manual

Page 129
5.8 PEP Virtual Port
The PEP Virtual Port object specifies components of the PEP Table, which is used to
configure ingress port filtering. PEP Table entries define traffic flows from the provider
network to the customer edge port.
The table is indexed by ComponentID and S-VID.
The columns allow the default C-VID value and default User Priority to be specified and
PEP's ingress filtering operation to be controlled.
5.8.1 PEP Virtual Port Commands
5.8.1.1 Set
C
reate and modify PEP Virtual Port elements using the Set command:
Set pep-vp <c-comp-id-list> s1 <vid-list>
[cpvid <vid>]
[prio 0..7]
[admit all | tagged | untagged]
[filter enabled | disabled]
If the PEP Virtual Port entry does not already exist, the Set command creates it and assigns
the attributes specified. Upon creation, in the event that an attribute is not explicitly
specified, the entry is created with the default value for that attribute.
If the PEP Virtual Port entry already exists, then the Set command will replace the attributes
that are currently defined for the entry with those specified in the command.
Note the following conditions for execution:
The Set command is valid only for those bridge ports which are S-component
ports.
Creating a new PEP Virtual Port entry fails if the port specified belongs to a S-
component and not a C-component.
The Set command operation also fails if the S-VID specified is not yet defined in
the VLAN Table.
5.8.1.2 Show
Display PEP Virtual Port entries using the Show command:
show pep-vp [{<c-comp-id-list> | all}
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299