Specifications
Chapter 4 Configuration FibeAir 4800 Installation and Operation Guide
4-18 FibeAir 4800 Installation and Operation Guide
Table 4-2. Typical Transmit Power Limits
Regulation Version Min Tx
[dB]
Max Tx
[dB]
MaxTx at
36 Mbps
[dB]
MaxTx at
48 Mbps
[dB]
Power
Control
F58 4 16 14 10 Yes
F58/EXT 4 16 14 10 Yes
F49 14 15 15 14 No
F53 -3 8 8 8 Yes
F53/EXT 3 3 3 3 No
F24 18 18 18 18 No
FCC
F53HP 10 16 14 10 Yes
India F58CN -1 10 10 10 Yes
China F24/EXT/ETSI -4 -4 -4 -4 No
F54 2 8 8 8 Yes
F54/ETSI 2 8 8 8 Yes
ETSI
F54-HG/EXT -3 3 3 3 Yes
4.8 Defining the Management Addresses
Each site must be configured separately, first site A then site B.
®
To define the Management Addresses:
1. Click Configuration from the main menu.
2. Select which site to configure.
The Configuration dialog box opens.
3. Select Management (see Figure 4-12).
4. Enter the IP address of the ODU in the IP address field.
If performing configuration from the FibeAir manager, the IP address is entered in
the login screen (Figure 2-4)
5. Enter the Subnet Mask.
6. Enter the Default Gateway.
7. Enter the Trap Destination. This is the IP address of the PC running the
management application. The event log will be stored at this address.
8. Click Apply to save the changes.