Specifications

Chapter 2 Installation and Setup FibeAir 4800 Installation and Operation Guide
2-8 FibeAir 4800 Installation and Operation Guide
The unit turns on automatically upon connection to the mains.
The green PWR indicator turns on, and the IDU indicator blinks orange for
approximately 40 seconds during startup. See Normal Indicators section in
Chapter 3.
After approximately 20 seconds the ODU starts beeping. The beeps
continue until the ODUs are aligned and the link set up.
3. Wait for approximately one minute, then repeat for Site B.
Connecting Power to an IDU-C
AC power is supplied to the FA4800 IDU-C through a standard 3-prong plug.
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated
by a standard 3-prong socket. A cable is provided with the unit.
®
To connect AC power to an IDU-C:
1. Connect the power cable socket to the power connector on the FA4800 front
panel.
2. Connect the power cable plug to the mains outlet.
The unit turns on automatically upon connection to the mains.
®
To connect DC power to an IDU-C
A special IEC 60320 adapter for-48 VDC power connection is supplied with the
unit.
2.10 Starting the FA4800 Manager Software
®
To start the FA4800 Manager:
1. Connect the management station to the LAN.
2. Double-click the FA4800 Manager icon on the desktop, or click Start >
Programs > FA4800 Manager.
The Login dialog box appears.