Specifications

Chapter 1 Introduction FibeAir 4800 Installation and Operation Guide
1-8 FibeAir 4800 Installation and Operation Guide
T1 Interface
Data Rate
Unframed (transparent) 1.544 MHz
(Specification may be different per ordering option)
Zero Suppression
AMI, B8ZS
Connector
RJ-45
No. Of Ports
IDU-E: 1 or 2
IDU-C: 4
Indicators
PWR (green) Power status (IDU-E only)
IDU (green)
IDU-C status
ODU (green/red)
ODU-to-IDU link status
AIR I/F (green/red)
Air Interface status
SERVICE (green/red)
E1/T1 signal status
Power
Source
IDU-E: 100–240 VAC via external AC/DC converter
IDU-C: 100–240 VAC via AC cable
-48 VDC (-42 to –60 VDC)
24 VDC
Power Received by
the ODU
-48 VDC
Power Consumption
ODU plus IDU-E – 10W max
ODU plus IDU-C – 14W max
Connector
IDU-E 2-pin
IDU-C AC – 3-pin IEC connector
DC – 3-pin terminal block
Connector
DB-9 female
Alarm
Connector
Electrical Characteristics
Dry Contact, 30V/2A
Max input current, 0.01A at 0.5W (R=5K)
Physical
Outdoor Unit (ODU)
With integrated antenna
Height
24.5 cm / 9.3 in 30.5 cm / 12 in
Width
13.5 cm / 5.13 in 30.5 cm / 12 in
Depth
4.0 cm / 1.57 in 5.8 cm / 2.3 in
Weight
1.0 kg / 2.2 lb 1.5 kg / 3.3 lb
Indoor Unit IDU-E IDU-C
Height
4.5 cm / 1.7 in (1U) 4.5 cm / 1.7 in (1U)
Width
23.5 cm / 9.3 in 29 cm / 11.5 in
Depth
16.5 cm / 6.7 in 43 cm / 17.7 in
Weight
0.5 kg / 1.1 lb 1.5 kg / 3.3 lb
Environment
Outdoor Unit (ODU)
Enclosure
All-weather case
Temperature
-35 to 60°C/-31 to 140°F