Specifications

Appendix D AIND Antenna Alignment Procedure FibeAir 4800 Installation and Operation Guide
D-4 FibeAir 4800 Installation and Operation Guide
Use a spectrum analyzer with suitable sensitivity to measure the signal at the
distance between the sites.
If nothing improves the receive power level, check the overall link.
Reduce the distance of the link–move the equipment from one site closer to
the other site–where it is possible to actually see the antennas with the naked
eye.
If you now get the expected receive signal level, you can assume that the
equipment is operational, and the problem arises from interference between
the sites.