Installation Instructions Chapter 4
FibeAir 1500 Installation & Operation Manual Chapter 4. System Setup
4-8 The Setup Procedure Revision 2.0
4.2.6. Setting the Transmit Power level
To set the transmitter power, perform the following operations:
1. Connect to the Terminal.
2. From the Main Configuration menu, select Full Configuration.
3. From the Full Configuration menu, select (6) ODU Configuration. The
ODU Configuration menu appears.
Figure 4-6 FibeAir 1500 Terminal - ODU Configuration Menu
4. Select (1) Transmit level.
5. Enter the desired transmit level. The acceptable values are between
–10 dBm to +15 dBm. Take into account the received level you expect
(the default received level is +15 dBm).
6. Select (S) Save & Return to save the settings and return to the Full
Configuration menu.
For frequencies other than 38 GHz, the transmit level can be higher than
15 dBm. Refer to Appendix E for more details.