How-To Guide Chapter 5

FibeAir 1500 Installation & Operation Manual Chapter 5. Operation
Revision 2.0 Windows and Menus 5-17
Setting Local Device Communication Parameters
Figure 5-18 Local Device Communication Parameters
1. In the
SLIP IP Address
field, set the SLIP IP Address column to zeros.
For further information regarding serial communications, please refer to
sections 4.2.7 – 4.2.9 and to Appendix D.
2. (Optional) In the
SLIP Modem phone number
field, enter the phone
number to be dialed by the IDU when traps are issued..
3. In the
Baud Rate
field, select the baud rate of your modem.
The baud rate of the NMS terminal and the FibeAir 1500 system must
match in order to provide a valid connection between the NMS terminal and
the IDU. By default, the IDU’s baud rate is set at 19,200. For details on how
to set the PC baud rate, refer to section 3.9.7.
Defining the Managers List
The Managers List section of the System Configuration window allows you
to define up to three managers to whom the systems alarms will be sent.
Figure 5-19 Managers List
Enter the IP addresses of up to three system managers.