User's Manual Part 9

Installation Instruction
Supplement for Installation Instruction 4 and 6-foot Antennas
Loosen the 4 bolts M5x25
Adjust the feed carefully.
-
for the vertical polarization, V to TOP-direction
-
for the horizontal polarization, H to TOP-direction
Lock the 4 screws M5x25
Connection of a standard wave guide flange
Loosen the 4 bolts M3x12
Remove the Adaptation and the O-Ring carefully from the feed
Attention: UBR-flange on antenna feed.
-
5
°
+
5
°
Adapter
O-Ring
M3 x 12
M5 x 25
V
Polarization adjustment with Ceragon-Adaptation