Please note that the brackets “<“ and “>“in the following commands are not part of the commands but
are included in order to increase the readability of the overview!
Four additional alarm numbers (mobile phones) can be defined using C2: - C5: commands. These
numbers are allowed to set relay 1 by a call and they are informed vian SMS in case of Start-up or
events. These numbers are not allowed to send configuration SMS messages unless they include the
password in the SMS.
If an alarm number is given in international format, the number must start with ‘+’. (e.g.
+491721234567)
With the command “PN:<4digit password>.” the password can be changed. The password can
include letters and figures but special characters are not allowed. All letters have to be in capital.
The texts of the event or start-up SMS can be changed with the commands “E1:<text1>.”,
“E2:<text2>.”… and “PT:<startup text>.”. The message length must not exceed 64 characters. Do not
use command syntax inside a message text. The ‘.’ is the terminating character of the text. Each new
text must be sent in a separate SMS.
You can generate an extended clip list of 1000 clip numbers. The numbers stored in the clip list are
allowed to switch relay 1 with a phone call. Use “CL:” to generate the clip list and add further phone
numbers. With “CD:” you can delete a phone number from the list. Be aware that you cannot read
out the clip list (getting SMS messages) because it could by far exceed the size limitation of SMS
texts.
With the command “TOx:<text>.” (x = 1 to 10, see command list above) an E-Mail address for the
particular events is configured. 5 E-Mail Adresses can be configured, divided by <;>.
The maximum length of the particular E-Mail addresses is 25 signs.
With the command “SUBx:<text>.” (x=1 to 10, see command list above) the subject of the particular
E-Mails is configured. The maximum number of sings for the subject is 128 signs. The predefined
text is: “STD32 Event x”.
The content of the E-Mail is configured with “BODY:<text>.”. The maximum length is 143 signs.
The E-Mail sender address (of the STD32) is changed with “FROM:<text>.”. The maximum length is
25 signs.
Please note that all commands listed in the section “Configuration SMS” require the 4-digit keyword at
the beginning.
6.5 Examples of SMS Commands
In the following examples, each command is preceded by a 4-digit password. Here, the password is set
to the value "9851", but it must be replaced with your unique password.
Task
SMS Command Sequence
Start-up alarm off, relay 1 on, relay 2 off, time
of activation of input 1: 5 sec
9851 S:0.O1ON.O2OFF.I1:5.
Switching time of relay 1 = 90 seconds
9851 O1:90.
Reset settings to factory settings
9851 R:
Configuration of the second alarm number
9851 C2:+491721234567.
Deleting a alarm number
9851 C2:"".
Configuration of a new password
9851 PN:AB12.
Adding a new clip to the extended clip list
9851 CL:+491721234567.