4 Power consumption
The following table shows you the power consumption of the GT864 Quad / PY in different
modes:
[mA] @ 5V
[mA] @ 12V
[mA] @ 24V
[mA] @ 32V
GT864 off
0,075
0,520
1,770
2,580
GT864 idle mode
52
22
16
14
GT864 with voice
call
203
86
41
40
Table 9: Power consumption of the GT864 Quad
[mA] @ 5V
[mA] @ 12V
[mA] @ 24V
[mA] @ 32V
GT864 off
0,080
0,557
1,768
2,596
GT864 idle mode
61
26
17
17
GT864 with voice
call
207
87
43
42
Table 10: Power consumption of the GT864 PY
Safety and Product Care
Please read the information in this section and the information in “Installation of the
Modem”, before starting your integration work!
4.1 Safety instructions
PLEASE READ THESE SAFETY INSTRUCTIONS AND KEEP A COPY OF THEM.
Always ensure that use of the modem is permitted. The modem may present a hazard if used in
proximity to personal medical electronic devices. As a rule, the modem must not be used in
hospitals, airports or planes.
Never use the modem at a gas station, refueling point, blasting area or in any other environment
where explosives may be present.
Operating the modem close to other electronic devices, such as antennas, television sets, and
radios may cause electromagnetic interference.
This product is intended to be used with the antenna or other radiating element at least 20cm
away from any part of the human body. In applications where this rule cannot be applied, the
application designer is responsible for providing the SAR measurement test report and
declaration.
You are responsible for observing your country's safety standards, and where applicable, the
relevant wiring rules.