95% Gas Furnace
Comfort, efficiency, and dependability make an unbeatable combination in the 95% gas furnace! ENERGY SAVINGS EASY-TO-CHANGE FILTER Two heat exchangers make this one of the most efficient furnaces on the market today. The primary exchanger pulls about three-quarters of the available heat from the burner, then the secondary heat exchanger captures most of what’s remaining.
UPFLOW SPECIFICATIONS MODEL GLUB 45-E3A 60-E3A 75-E3A INPUT-BTU/HR 45,000 60,000 75,000 HEATING CAPACITY BTU/HR 42,000 56,000 70,000 BLOWER (D x W) 11 X 7 11 x 7 11 x 7 1 1 1 MOTOR H.P.-SPEEDS-TYPE /2-4-PSC /2-4-PSC /2-4-PSC MOTOR FULL LOAD AMPS 6.8 6.8 6.8 HEATING SPEED MED-LOW MED-HIGH MED-HIGH COOLING SPEED HIGH HIGH HIGH HEAT EXT. STATIC PRESSURE (IN. W.C.) .10 .12 .12 MAX. EXT. STATIC PRESSURE (IN. W.C.) .50 .50 .50 HEATING CFM @ .2” W.C. E.S.P. 885 845 1050 COOLING CFM @ .5” W.C. E.S.P.
UPFLOW DIMENSIONS UPFLOW DIMENSIONS AND CLEARANCE GLUB MODEL 45-E3A 60-E3A 75-E3A 75-E4A 90-E5A 105-E5A A B C D 171/2 171/2 171/2 21 21 21 1611/32 1611/32 1611/32 1927/32 1927/32 1927/32 155/8 155/8 155/8 191/8 191/8 191/8 2 2 2 2 2 2 STANDARD EQUIPMENT MINIMUM CLEARANCES (IN.
DOWNFLOW / HORIZONTAL SPECIFICATIONS MODEL GLDB 45-E3A 60-E3A INPUT-BTU/HR 45,000 60,000 HEATING CAPACITY BTU/HR 41,000 56,000 BLOWER (D x W) 11 X 7 11 x 7 1 1 /2-4-PSC /2-4-PSC MOTOR H.P.-SPEEDS-TYPE MOTOR FULL LOAD AMPS 6.8 6.8 HEATING SPEED MED-LOW MED-HI COOLING SPEED HIGH HIGH HEAT EXT. STATIC PRESSURE (IN W.C.) .10 .12 MAX. EXT. STATIC PRESSURE (IN W.C.) .50 .50 HEATING CFM @ .2” W.C. E.S.P. 866 1122 COOLING CFM @ .5” W.C. E.S.P.
DOWNFLOW / HORIZONTAL DIMENSIONS DOWNFLOW MODELS GLUB MODEL 45-E3A 60-E3A 75-E4A 90-E5A 105-E5A A B 171/2 171/2 21 21 241/2 1611/32 1611/32 1927/32 1927/32 2311/32 MINIMUM CLEARANCES (IN.
Space Saving, Energy Saving Gas Heat Source IN-SHOT BURNER PRIMARY HEAT EXCHANGER Engineered to provide the most efficient air/gas mixture for combustion, the shutter-free design requires no adjustments to regulate the mix The patented tubular design extracts heat from combustion gases; made of highest quality materials, it is resistant to corrosion and thermal fatigue, and it’s covered by a limited lifetime warranty DRAFT INDUCER ELECTRONIC IGNITION Specially designed for the tubular heat exchanger,
UPFLOW ACCESSORIES VENT TERMINATION KITS CONCENTRIC HORIZONTAL/VERTICAL: RXGY-E03A (US and Canada) HORIZONTAL TWO PIPE: HXGY-D02, HXGY-D03, HXGY-D04 (US only) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canada only) RXGY-G02 (US only) NEUTRALIZER KIT: RXGY-A01 FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM: 7603-639, 7603-640, 7603-641* *May be installed only on side opposite gas pipe and electrical.