Specifications
Century S245E Installation and Operation Manual
30
CLEARANCES (SINGLE WALL PIPE)
CANADA USA
A
15½" (394 mm) 15" (381 mm)
B
18" (457 mm) 18" (457 mm)
C
10" (254 mm)* 10" (254 mm)*
D
18" (457 mm) 17½" (445 mm)
E
26½" (673 mm) 26½" (673 mm)
F
20" (508 mm) 20" (508 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)
Note: These clearances are also valid for an alcove installation.
*If ceiling height (L) is between 68’’ and 84’’, clearance (C) changes to 12’’ (305 mm).
CLEARANCES (DOUBLE WALL PIPE)
CANADA USA
A
10" (254 mm)* 10" (254 mm)*
B
18" (457 mm) 18" (457 mm)
C
10" (254 mm) 10" (254 mm)
D
12½" (318 mm) 12½" (318 mm)
E
26½" (673 mm) 26½" (673 mm)
F
18" (457 mm) 18" (457 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)