Installation manual

Buzzer feedback
A warning buzzer will sound (where applicable) as per the table below:
Inhibitor
name
Break-in alarm
Ambush alarm
Auxiliary overload
Holiday Lockout
Emergency stop
No limits set
Mains failure
Beams broken
(any)
Beams failure
Fuse blown
Motor
disconnected
Bridge
damaged
Gate
stalled
Multiple collision
Battery low
Number
of beeps
Continuous tone
for 30 seconds
Continuous tone
until IRBs are cleared
5 beeps periodically
for 30 seconds
1 beep periodically
for 30 seconds
1 beep periodically
for 30 seconds
3 short beeps for
5 seconds
2 beeps periodically
for 30 seconds
1 beep periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
5 beeps periodically
for 30 seconds
4 beeps periodically
for 10 seconds
Periodic until condition
is cleared by user
(500/500ms)
3 beeps periodically
for 30 seconds
Priority
1
2
5
6
7
9
10
11
12
14
15
16
17
3
4
Fault
type
Alarm
Alarm
Hardware
User
User
Lost
Power system
fault
User
Hardware
Hardware
Hardware
Hardware
Collision
Collision
Power system
fault
Gate
continues
to operate
N/A
N/A
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes*
User can
correct
error
N/A
N/A
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Gate will close fully and then shutdown for two minutes
*