Installation manual
25. Diagnostics
Diagnostic LEDs
The controller is fitted with diagnostic lights (LEDs) that assist with the set-up and
maintenance of the gate.
Table 2 below provides a description and purpose of the indicator lights with Figure 71
alongside, indicating the location on the control
M Sens1
M Sens2
Light
Sens+
Sens-
Safe CLS
Safe OPN
Com
LCK/STP
TRG
PED
Com
FRX
LIT
LED
Com
Aux 12V
Safe Com
Sol
Slow regular flash Gate is opening
Fast regular flash Gate is closing
One flash every two seconds Courtesy Light latched on
Two flashes every two seconds Mains Failure
Three flashes every two seconds Battery Low
Four flashes every two seconds Collision Shutdown
Four flashes every two seconds Multiple Collisions have occurred
Gate status LED
Safety close
On when the closing beam is not activated
Off when closing safeties obstructed
Safety open
when the opening beam is not activatedOn
Off when opening safeties obstructed
Lck/Stp
when system ready to operateOn
Off when system locked
Trg
when the trigger signal is presentOn
Off when no signal
Ped
when the pedestrian signal is presentOn
Off when no signal
FRX
when a free-exit signal is presentOn
Off when no signal
Lit
when signal presentOn
Off when no signal
LED
On when gate open
Off when gate closed
FIGURE 71