Installation manual
Page 29
FIGURE 44
FIGURE 45
1400mm Extended
1000mm Retracted1000mm Retracted
For V400 (400mm operator)
120°
100°
110°
90°
80°
70°
60°
Gate opening angle
0°
Gate swing angle
90° or less
100°
110°
120°
A Value
150
155
125
110
B Value
150
155
125
110
(Only for a 2.5m gate or shorter)
Recommended positions
Alternative positions
100mm for A or B would ensure a 10mm clearance between the operator and
gate if the gate is 50mm thick
Gate swing
angle
60° - 90° or less
100°
110°
120°
A+B should not
exceed
380mm
325mm
275mm
230mm
A and B must each be greater
Up
to1.5m
100mm
Up to
2m
100mm
Up to
2.5m
100mm
Up to
3m
120mm
Up to
3.5m
140mm
Up to
4m
160mm
Not recommended










