Installation manual

Page 9
VECTOR2 400 VECTOR2 500
Input voltage
Motor voltage
Motor power supply
Battery charger
Domestic
Light-industrial
Current consumption (mains)
Current consumption (motor at rated load)
Operator push force - maximum
Operator stroke
Piston extension / retraction speed
Typical gate opening time
Manual override
Maximum number of operations per day
Duty cycle - mains present
Operations in standby with 7Ah battery
Half day
Full day
Collision sensing
Controller solenoid output rating
Operating temperature range
Onboard receiver type
Receiver code storage capacity
Receiver frequency
Mass of unit packed (excluding battery)
Single kit
Double kit
220-240V AC ± 10%, 50Hz
12V DC
Battery driven (standard capacity - 7Ah)
CP84E - 800mA @ 13.8V
CP84SM - 2A @13.8V
60mA / 170mA
15A - max
250kgf
27mm/sec
Key release
100 / 250
25% / 50%
70
58
Electronic
2A DC
-15°C to +50°C
CENTSYS code-hopping
multichannel
64 transmitter buttons
433MHz
400mm 500mm
<14 sec
<17 sec
8.5kg
14kg
9kg
15kg
Can operate off a solar supply, consult CENTSYS for assistance
Can increase battery capacity for longer standby times
Based on 25°C ambient temperature and unit not in direct sunlight
Based on an operator push force of less than 50% of rated
Based on double kit excluding infrared safety beams
Assumes a 90° opening gate and optimum mounting position
Assumes full stroke of operator is used
Technical specifications