Operating Instructions and Installation Instructions

18
Page 18
Connected loads
230 Volt, 0,25 KW
Pull and Push force
500N
Carriage travel
Ca. 0,12 cm/sec with soft start and soft stop.
Garage light
Automatic shut off after ca. 3 minutes
1 x 40 W max., E14 light bulb (not included)
Motor and transformer
Direct Current geared motor,
Regular current transformer with Thermal
protection
Motor control
Microprocessor controlled
Motor control voltage
Low voltage ca. 24 Volt
Output power for accessories:
about 24 VDC, 50 mA max.,
short circuit protected
Operational time
Operational duration max. KB 2 min
Protection category
For inside use only (dry buildings)
TECHNICAL SPECIFICATIONS
- Make sure everything is assembled and
installed correct.
- Fasten all screws, nuts and bolts.
- Check if garage door is well balanced and
lubricated.
Noisy operation.
- Check if transmitter codes are programmed
- Check transmitter battery
- If external receiver check wire connections to
terminal Nr. 5, 6 and 7.
- If 3-function wall console the 'vacation lock'
may be activated
Transmitter does not function but wall
control does.
- Check mains
- Check terminal Nr. 3 and 4. connections
- Check wall button connections and cable in
between operator and wall control
Operator does not work via wall control.
- Check limit clip positions
Door does not close or open completely.
- Check opening lifting force settings
Door stops in opening motion.
- Check closing push force settings
Door stops and reverses in closing motion.
- Check limit clip positions; is open switch on
correct side of chain or belt?
- Check if operator is programmed to have a
beam break?
- Check beam break
N
OTE: IN CASE ONE HAS TO CLOSE THE GARAGE
DOOR IT IS POSSIBLE WHEN ONE PRESSES
THE WALL CONTROL BUTTON CONTINUOUSLY
UNTIL DOOR IS FULLY CLOSED
.
Door does not close even though power
is connected.
TROUBLESHOOTING
Troubleshooting
Technical specifications