Specifications

page 17
Features
and
functions
The D5-Evo and D10
incorporate a sensitive electronic
anti-crushing technology that
activates if a person or vehicle
obstructs your gate.
The operator will respond
differently to obstructions
depending on the Operating
Standard (e.g. CE, UL325) you
select. The typical response for
an opening gate is to
immediately stop and a closing
gate will stop then immediately
reopen.
Collision force can be set
independently per direction of
travel and can be set from
minimum to maximum in five
incremental steps. A sixth
incremental step will disable
collision sensing entirely and
allow for maximum force – the
motor will run until it stalls at
which point a collision will be
detected.
Step six should only be used if additional safety measures
such as Infrared beams and sensitive edges are present.
5.1.10. Anti-crushing Sensitivity
&
5.1.10.1. Collision Count
A counter monitors the number of collisions the gate experiences
before it fully closes. If the number exceeds the default value of
four, which can be adjusted in the Multiple Collisions Counter, the
controller will shut down. The Status LED (page 20) will flash four
times every second until a valid trigger is received.
Please refer to Gate Status Indication (page 20) for more
information on this diagnostic device.
FIGURE 22
FIGURE 23