SPECIFICATIONS
Power Supply
Maximum absorbed current
Motor voltage
Output pinion
Starting thrust
Rated thrust
Operating speed @ rated thrust
Motor cooling
1
Duty cycle (continuous)
1
Duty cycle (½ hr endurance)
Ambient temperature range
Anti-crushing sensing
Motor thermal protection
Maximum gate length
IP rating
Optional battery backup
Shipping mass of unit
A10 ENDURANCE A10
220-240V +/- 10%, 50Hz - Single-phase
220-240V +/- 10%, 50Hz - Single-phase
6A
220-240V three-phase
17 Tooth Mod 4
47kgF
35kgF
13.6m/min
High Efficiency Fan (2300 RPM)
90%
95%
O O
-20 C to +50 C
Electronic
Electronic
17m
44
Yes
15.6kg
40kgF* 30kgF**
30kgF*
22.5KgF**
6A
220-240V three-phase
20 Tooth Mod 4
2
Adj. Up to 30m/min
16m/min
High Efficiency Fan (2300 RPM)
90%
95%
O O
-20 C to +50 C
Electronic
Electronic
20m
44
Yes
15.7kg
1 000kg* 600kg**
2 000kg
Maximum gate mass
SPECIFICATIONS
Input voltage
Input current @ rated thrust
Rated output voltage
Battery charger
Maximum duty cycle
Thermal protection
Enclosure
Dimensions
Maximum battery size
4
Open and close cycles
Shipping mass
DC CONVERTER
12V DC
30A
310V DC
1A
20%
Electronic
IP65 External Plastic Enclosure
310mm x 240mm x 110mm
3
Page 24
O
(1) At rated thrust and 25 C maximum ambient temperature, unit in full shade.
(2) Refer to RATED THRUST values.
(3) Upgradable on request.
(4) Dependant on site / environmental conditions.
12V 7Ah (External 35Ah optional)
7 - 12 (7Ah battery) 40 - 70 (40Ah battery)
10kg (Inc 7Ah battery)