Specifications

16 Rockwell Automation Publication 2094-RM002B-EN-P - May 2012
Chapter 2 Installation and Wiring
Using the 2090-K6CK-D44S0 Low-profile Connector Kit
The 2090-K6CK-D44S0 connector kit includes two motion-allowed jumpers.
Remove the jumpers to wire the safe torque-off connections. Install the jumper
when your application is not using the safe torque-off functionality, but your
application requires I/O connections.
The 2090-K6CK-D44S0 connector kit lets you cascade the safe torque-off
signals from drive-to-drive by using the 2090-CS0DSDS-AAxx interface cable.
Figure 2 - Making 2090-K6CK-D44S0 Safety Connections
Refer to the Kinetix 6200 and Kinetix 6500 Modular Servo Drive User Manual,
publication 2094-UM002
, for other wiring examples using low-profile connector
kits.
IMPORTANT
You must remove the motion-allowed jumpers to wire the safe torque-off
connections.