Instruction manual
14
12.7 Changing the Normal/Bypass Code and Door Chime Settings
The Normal/Bypass Code is also used to turn the Door Chime off and on.
1. Enter Programming Mode.
2. Press “5” to enter Menu 5.
TheModeLEDashesorange.
3. Program the Normal/Bypass Code and Door Chime in
one of the following four different ways:
•DisabletheBypassModeanddisabletheDoorChime:
Enter the 4-digit code 0000.
•DisabletheBypassModeandenabletheDoorChime:
Enter the 4-digit code 0001.
•EnabletheBypassModeanddisabletheDoorChime:
Enter any 4-digit code ending with 0.
•EnabletheBypassModeandenabletheDoorChime:
Enter any 4-digit code not ending with 0.
The system returns to Normal Mode:
•3beepsareemitted.
•TheDoorLEDturnsoff.
•TheModeLEDturnsgreen.
Note : The Door is only generated when the Lock Strike Relay is activated due to a valid code
entry.
12.8 Setting fail Safe/Secure Operation, Tamper Siren Time, and Lock Strike Release Time
1. Enter Programming Mode.
2. Press “6” to enter Menu 6.
TheModeLEDashesgreen.
3. Construct the 4-digit code using the following instruction.
•Firstdigit:ForFailSecureOperation,entera“0”;
For Fail Safe Operation, enter a “1”.
•Seconddigit:TamperSirenTime;enterthenumber
of minutes (from “1” to :9:).
•Thirdandfourthdigit:LockStrikeReleaseTime;
enter the number of seconds (from “1” to “99”)
after which you want the Lock Strike to be released.
For example : 0 5 1 2 means Fail Secure Operation, with a 5 minute Tamper Siren Time, and a
12 second Lock Strike Release Time.
The system returns to Normal Mode:
•3beepsareemitted.
•TheDoorLEDturnsoff.
•TheModeLEDturnsgreen.