User guide

116 TALKSWITCH USER GUIDE
Other options include:
Voicemail Screening (used in a home environment)
Demo with a router (used for demonstrating the product)
Static VoIP Demo (used strictly for demonstrating two TalkSwitch units
connected to a hub or a switch and acting as two separate locations.
Auto Attendant Transfer Prompts
TalkSwitch can disable playing of transfer prompts to callers when redirecting
calls from the auto attendant.
SIP Server Registration
Select the Re-registration Interval between 2 and 60 minutes from the drop-
down list. The re-registration interval on your IP phones may differ, but
TalkSwitch will use the time specified here. See Figure 105 on page 110.
2.6.5 Troubleshooting
Do not change the following controls unless you are familiar with the effect
they have on the TalkSwitch operation. If your system does not appear to be
functioning properly, please contact your dealer for assistance.
Figure 106: Troubleshooting
Flash lengths
Accepted Flash length:
These options control the flash length allowed from a local extension that
TalkSwitch considers to be an intentional flash. The range can be adjusted to
accept anything from 300 ms to 1 second. The default range for accepting a
flash signal at a local extension is between 400 ms and 800 ms. Most phones
emit a 600 ms flash signal when the Flash or Link button is pressed.