APPENDIX A
Connecting power through building wiring
TS-600 can be powered through building wiring from a wiring distribution
frame, provided all building wiring requirements are met.
The TS-600 cord adapter, AC adapter, short line cord must be located near the
wiring distribution frame and phone system (e.g. TalkSwitch).
1. Connect the AC adapter to an electrical wall outlet, and connect the AC adapter
end plug to the DC jack of the cord adapter. The LED will light to indicate DC
power is available.
2. Connect one end of the supplied short line cord to the TO LINE jack of the
cord adapter, and the other end to your phone system (e.g. TalkSwitch
extension jack).
3. Connect one end of a 6-pin, 6-conductor (6p6c) RJ11 cable* (not supplied)
from the TO PHONE jack of the cord adapter and connect the other end to the
appropriate point on the distribution frame. (*also known as RJ25 cable)
4. Using CAT3/5e cable (maximum
length 100 m/328 ft) wired as
shown at right, connect the
distribution frame terminal to
the RJ11 telephone wall jack
that will connect to a TS-600
telephone. (This is required for
each TS-600 wall jack).
5. At the TS-600 location, connect one end of the supplied long line cord to the
TEL LINE jack on the TS-600 phone, and the other end to the RJ11 telephone
wall jack.
RJ11 6p6c RJ11 6p6c CAT3/5e
Wire Colour (RJ25) pins Wire Colour
white/green 1 white/green
(not used) 2 (not used)
blue 3 blue
white/blue 4 white/blue
(not used) 5 (not used)
green 6 green