Install guide
CentreCOM
®
AT-3726 XL,
AT-3716 XL
Switches
QUICK
INSTALL
GUIDE
PN 613-10769-00 Rev. A
Caution
The RS232 port is for Setup and Diagnostics only. The cable
must be disconnected during normal operation to maintain
Emissions Compliance.
Workgroup Switch Configuration
This configuration shows the AT-3726XL switch used for a group of
heavy-traffic users in a large corporate network. In this example, the
switch is brought to the desktop with a single end-station per switch port.
A local server is connected to the 100 Mbps Fast Ethernet link and the
optional 100 Mbps port connects to the corporate backbone.
Settings Default
IP Address 0.0.0.0
Subnet Mask 0.0.0.0
Gateway Address 0.0.0.0
Get community string public
Set community string private
Trap community string public
Port mirroring state Disabled
Spanning Tree Protocol Disabled
Telnet Access Enabled
System Name None
Password (Omega) No password assigned
Download Password ATS20
Port Priority 128
Port Path Cost 100
Half-duplex or Auto-negotiate (per port) Auto-negotiate (AT-3726XL, AT-3716XL)
Half-duplex (AT-3714FXL)
High Speed Port Speed 100 Mbps
Spanning Tree Priority 32768
Active Aging Time 300 seconds
Hello Time 2 seconds
Transmit Pacing Disabled
Bridge Identifier (STP) 32768 (bridge priority)
Port Priority (STP) 128
Port Cost (STP) 100 for 10 Mbps ports
10 for 100 Mbps ports
Store-and-forward or Cut-through
(fragment-free)
Store-and-forward
Domain name None
Timeout 5 minutes
Default VLAN Name Default VLAN
Where To Find Allied Telesyn and Technical Publications
Location Phone/Fax
Americas
U.S.A., Canada, Mexico, Central America, South
America
1 (800) 428-4835
1 (918) 628-3222
Asia
Singapore, Taiwan, Thailand, Malaysia,
Indonesia, Korea, Philippines, China, India
(+65) 3815-613
(+65) 3833-830
Australia
Australia, New Zealand
(+61) 2-9438-5111
(+61) 2-9438-4966
France
France, Belgium, Luxembourg, The Netherlands,
Middle East, Africa
(+33) 1-60-92-15-32
(+33) 1-69-28-37-49
Germany
Germany, Switzerland, Austria, Eastern Europe
(+49) 30-435-900126
(+49) 30-435-70650
Hong Kong (+852) 2-529-4111
(+852) 2-529-7661
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel
(+39) 2-416047
(+39) 2-419282
Japan (+81) 3-3443-5640
(+81) 3-3443-2443
United Kingdom
United Kingdom, Denmark, Norway, Sweden,
Finland, Iceland
(+44) 1-235-442560
(+44) 1-235-442490
Technical Bulletin Board 1-425-483-7979
Technical Support E-mail Address TS1@alliedtelesyn.com
CompuServe Go ALLIED
Internet, World Wide Web and FTP site http://www.alliedtelesyn.com
MDA
B
100BASE-TX
A
MIRROR PORT
RS-232
TERMINAL PORT
STATUS
10BASE-T
PORT ACTIVITY
Workstations
Server
Uplink to corporate LAN
AT-3726XL
Legend
Dedicated 10Mbps link
Dedicated 100Mbps link
using MDA
For 100 Mbps ports;
auto-negotiation
for 100Base-TX
Visit our technical publications website at:
www.alliedtelesyn.com
manuals.ht
AT-3726XL, AT-3716XL, and AT-3714FXL
Related Guides
Web Printed
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide,
613-10766-00 (shipped with product)
✔
AT-S20 User’s Guide, 613-10716-00
✔
AT- 3714FXL Quick Install Guide,
613-10767-00 (shipped with product)
✔
AT-3714FXL Translated Safety Information Booklet,
613-10770-00 (shipped with product)
✔
AT-3726XL and AT-3716XL Quick Install Guide,
613-10769-00 (shipped with product)
✔
AT-3726XL and AT-3716XL Translated Safety Information
Booklet, 613-10768-00 (shipped with product)
✔
AT-A10 and AT-A11 Quick Install Guide,
613-10742-00 (shipped with product)
✔
Copyright
1998 Allied Telesyn International, Corp.
950 Kifer Road, Sunnyvale CA 94086 USA
All rights reserved. No part of this publication may be reproduced without prior written
permission from Allied Telesyn International, Corp.
Centre
COM is a registered trademark of Allied Telesyn International, Corp.
Ethernet is a registered trademark of Xerox Corporation. All other product names, company
names, logos or other designations mentioned herein are trademarks or registered trademarks of
their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other
information contained in this document without prior written notice. The information provided
herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be
liable for any incidental, special, indirect, or consequential damages whatsoever, including but not
limited to lost profits, arising out of or related to this manual or the information contained herein,
even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the
possibility of such damages.
6 7 8