User's Manual

Thermostat Programming
12:21(System Mode)
00: Cooling Only(COOL and OFF modes only)
01: Cooling with Reheat
02: Heating Only(HEAT and OFF modes only)
03: Heating with Reheat
04: Full Mode(AUTO, COOL, HEAT, OFF)
05: Full Mode with Reheat(AUTO, COOL, HEAT, OFF)
06: Manual Mode(COOL, HEAT, OFF) (DEFAULT)
07: Auto Mode(AUTO, OFF)
13:10(Calibration)
-09 to 09: Temperature Calibration(DEFAULT = 00)
14:11(Occupancy Differential)
00-99: Setback Differential 0.0 Degrees F to 9.9 Degrees F(DEFAULT = 03)
14:21(Occupancy Exit Delay)
00-99: Exit Delay in Minutes(DEFAULT = 15)
14:31(Motion Only)
00: Motion Only Enabled(DEFAULT)
01: Motion Only Disabled
15:11(Auto Mode Delay)
00-99: Minimum Delay in minutes between mode changes