Specifications

7
Integrated Semi-Automatic Dispensing System 97008/97009
Technical Specifi cations:
Power Supply 90-260 VAC; 47-63 Hz Power Consumption 25W
Air Input min. 5 bar (70 psi),
max. 10 bar (145 psi),
ltered to a maximum of 10 µm
Air Output 97008: 0.3-7 bar (10-100 psi)
97009: 0.1-4 bar (3-60 psi)
Dimensions (W x H x D) 360 x 335 x 235mm
Weight 7.5kg
Selector Chart:
System Description Item # IDH No.
Integrated Semi-Automatic Dispensing
System
without low level sensing 97008 215844
with low level sensing 97009 215845
Accessories: Item # IDH No.
Foot Switch 97201 88653
Airline Filter / Regulator 97120 88649
Features:
Integrated design for simple
setup and space economy.
Precision pressure regulator
(0.1-4 bar) for reliable dispensing,
eliminating air pressure fluctuation
(97009)
Pressure displayed by pressure
gauge 0-4 bar (97009) or 0-10 bar
(97008) respectively
Timer-controlled solenoid valve
for air-actuated applicator
Level sensor to give empty
warning (97009)
The Integrated Semi-Automatic Dispensing System is a compact unit providing time-controlled dispensing when
combined with an appropriate Loctite
®
dispensing valve. The system provides digital control of dispensing time within
the range 0.1-99.9 seconds. The controller can be actuated by a footswitch or finger switch . It is also capable of
operating in a continuous mode for bead dispensing applications. The reservoir accommodates Loctite
®
bottles in
250ml, 500g, 1 litre, and 2kg packages. The semi-automatic Dispensing System is required to be connected to an
external electrical and pneumatic supply. Reservoir pressure and dispensing time can be set independently of each
other. An uncovered bottle of Loctite
®
product is placed directly into the integrated reservoir, and the reservoir lid is
clamped in place. The reservoir is then pressurised using clean, filtered dry air. Air within the reservoir will push down
on the liquid in the bottle and force it through the product feedline to the dispensing valve. The amount of product
dispensed is controlled by three main factors: The pressure in the reservoir, the length of time the dispensing valve
remains open, and the dispensing needle size.
97009: The “empty” signal is indicated as blinking text “U” on the digital display of the controller. In addition it is
signalled by an audible alarm.
Additional features: Voltage free output signals for empty and ready signalling. These can be connected to a higher
ranking controller.
See pages 18-23 for Dispense Valve selection.