Specifications
G71
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
Flow
Controls
Integrated
Fittings
SensingControl
Panel
G
Accessories
PPS1 Series
Catalog 0600P-E
Pressure Switch
Operation
The pressure switch monitors the air
pressure in your pneumatic system.
When the pressure in your system
either drops below or exceeds the
set point pressure, an electrical
output is given.
3 (Normally Open)
2 (Normally Closed)
1
(Common)
➤
➤
➤
Pressure Switch – PPS1
Definitions and Terminology
Repeatability — Accuracy is the maximum allowable set
point deviation of a single pressure or temperature switch
under one given set of environmental and operational
conditions.
Single Pole Double Throw (SPDT) Switching element —
A SPDT switching element has one normally open, one
normally closed and one common terminal. Three terminals
mean that the switch can be wired with the circuit either
normally open (NO), or normally closed (NC), or both.
Dead Band — The dead band, sometimes referred to
as “differential” or “hysterisis”, is the change in pressure
between actuation and deactuation set points.
2.30
(58.4)
1.20
(30.5)
Max.
Ø
1/4-18 NPTF
1-1/8 Hex
18” Leads
1-1/8 Hex
2.50
(63.5)
1.50
(38.1)
1
GND
2
3
Top View DIN
Pin Configuration
Pin 1 - Common (Black)
Pin 2 - N.C. (Blue)
Pin 3 - N.O. (Red)
Wire Configuration
Pin 1 - Common (Black)
Pin 2 - N.C. (Blue)
Pin 3 - N.O. (Red)
Max.
1/8-27 NPT
Features:
• Long life elastomer diaphragm
• High quality snap action switch
• Field adjustable
• Compact design
• Easily customized
• Quick delivery
• NEMA 4, 13
Set Point Electrical
Thread Circuit Range Dirrection Connection
PPS1 - 1 C 3 - R HM
Ordering Information
Thread
1
1/4" NPT Male
2
1/8" NPT Male
17
1/4" BSPP Male
28
1/8" BSPP Male
Range*
1
3-10 PSI
2
6-30 PSI
3
20-120 PSI
4
100-400 PSI
†
†
Only available in
1/4" NPT
Electrical
Connection
HM
DIN 9.4mm
WL
Wire Leads
18"
Circuit
C
SPDT
Set Point
Direction
R
Rising
Note: Switch is field adjustable.
* Factory setting for
calibration purposes
Range 1 = 6 PSI
Range 2 = 18 PSI
Range 3 = 70 PSI
Range 4 = 250 PSI
(Revised 09-25-12)
Specifications
Set Point Tolerance ............................ ±1 PSI or 5% (.07 bar)
Temperature Range ............-40F° to 220F° (-40C° to 105C°)
Max. Operating Pressure
(Ranges 1, 2, 3) .........................................250 PSI (17.2 bar)
Max. Operating Pressure
(Range 4) ...............................................2000 PSI (137.9 bar)
Deadband ........................................10 - 20% of set pressure
Current Rating ............................................... 3A @ 125 VAC
2A @ 30 VDC (Resistive)
Circuit Form ..................................................SPDT Standard
Cycle Life ...................................................................1 Million
Materials of Construction
Adjustment Knob ..................................Anodized Aluminum
Body .............................................................................Brass
Diaphragm ...................................................................Nitrile