User Manual
CENDO – Handleiding Flex Inductie kookplaat KR99FI3TS
42
ENGLSH
• The isolating switch must be of an approved type and provide a 3mm air gap contact
separation in all poles (or in all active [phase] conductors if the local wiring rules allow
for this variation of the requirements).
• the isolating switch will be easily accessible to the customer with the hob installed
• you consult local building authorities and by-laws if in doubt regarding installation
• You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall
surfaces surrounding the hob.
When you have installed the hob, make sure that
The power supply cable is not accessible through cupboard doors or drawers.
There is adequate flow of air from outside the cabinetry to the base of the hob.
If the hob is installed above a drawer or cupboard space, a thermal protection barrier is
installed below the base of the hob.
The isolating switch is easily accessible by the customer.
Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not apply force
onto the controls protruding from the hob.
Locating the fixing brackets
• The unit should be placed on a stable, smooth surface (use the packaging). Do not apply
force onto the controls protruding from the hob.
• Fix the hob on the work surface by screw four brackets on the bottom of hob (see
picture) after installation.
• Adjust the bracket position to suit for different work surface’s thickness.
Cautions
• The hob must be installed by qualified personnel or technicians. We have professionals
at your service. Please never conduct the operation by yourself.
• The hob shall not be mounted to cooling equipment, dishwashers and rotary dryers.
• The hob shall be installed such that better heat radiation can be ensured to enhance its
reliability.
• The wall and induced heating zone above the work surface shall withstand heat.
• To avoid any damage, the sandwich layer and adhesive must be resistant to heat.
• A steam cleaner is not to be used.
• This ceramic can be connected only to a supply with system impedance no more than
0.427 ohm. In case necessary, please consult your supply authority for system
impedance information.